B2B Contract Drapery Supply

Flame Retardant Curtain Manufacturer

Custom flame retardant curtains, also commonly specified as fire retardant curtains, for hospitality, offices, commercial interiors and contract projects.

DISCUSS YOUR FR CURTAIN PROJECT

Visible Test Evidence

See a real burn comparison

The video compares standard and flame-retardant curtain fabric using the selected samples shown. Applicable fabric and supporting documentation are confirmed against the project specification.

Testing & Documentation

Match the report to the exact fabric and project

SGS reports are available for selected applicable materials. Before order approval, the buyer and Dairui must confirm that the report sample, fabric specification and required market standard match the project.

SGS NFPA 701 curtain fabric test report

NFPA 701

SGS report SL62206251632701TX, SGS-CSTC Hangzhou, 24 March 2022 — Method 1, woven curtain fabric.

SGS CAN/ULC-S109 curtain fabric test report

CAN/ULC-S109

SGS report SL62606316314601TX, SGS-CSTC Hangzhou, 4 June 2026 — 353 g/m² single-layer fabric. Afterflame 0 seconds on all eight specimens, char length 78–89 mm, no flaming drips.

We can develop flame-retardant curtain solutions to meet project requirements such as NFPA 701 or CAN/ULC-S109. The applicable fabric, construction and test documentation are confirmed based on the project specification before order approval. See the full test reports and certifications.

FR Curtain Solutions

Flame Retardant Curtain Solutions for Commercial Projects

Dairui supports finished FR curtains and drapery programs for buyers who need design control and a clear documentation path. Final compliance depends on the selected fabric, construction and required test method.

FR Blackout Curtains

For guest rooms, meeting spaces and other commercial interiors where light control and flame-performance requirements must be considered together.

Decorative FR Drapery

Color, texture, heading and finished dimensions can be developed for the interior scheme, subject to the available FR fabric route.

Project-Specific Supply

Suitable materials and documentation are reviewed against the buyer's market, application and specification before approval.

Material Routes

FR-treated vs inherently FR curtains

FR-Treated Fabric

A flame-retardant finish is applied to the fabric after weaving. Because the base fabric is chosen first and treated afterwards, this route keeps the widest choice of appearance, texture and colour.

The performance comes from the finish rather than the fibre, so care method and expected service life should be confirmed for the exact fabric and intended use.

Inherently FR (IFR) Fabric

The flame-retardant property is built into the polyester fibre itself rather than applied as a surface finish after weaving, so it does not wash out.

Composition
100% IFR polyester yarn
Width
280 cm
Sheer / voile
around 100 gsm
Blackout
200–260 gsm standard; heavier constructions to 300+ gsm on request
Supply
By the roll, or converted into finished curtains in our own curtain factory.

Under flame exposure, IFR fabric shrinks away from the heat source and forms a char area that limits flame spread; once the ignition source is removed, a correctly specified IFR fabric is designed to self-extinguish. Flaming-droplet behaviour should be assessed from the test report for the exact construction, rather than assumed from the IFR designation alone. Testing is arranged per order against the standard required by the destination market — for example NFPA 701 or CAN/ULC-S109.

Customization

Develop the curtain around the interior and compliance brief

Fabric & Appearance

Review blackout or decorative fabric, color direction, texture and drape together with the required FR route.

Finished Curtain Details

Specify finished dimensions, heading style, lining, fullness direction and installation interface for project review.

Brand & Delivery Details

Labels, packaging and project identification can be discussed as part of the approved order specification.

Commercial Applications

For hospitality and contract interiors

Hotels & Hospitality

Guest rooms, suites, lobbies, meeting rooms and other hospitality spaces.

Offices

Workplaces, meeting rooms and managed commercial properties.

Commercial Interiors

Retail, public-facing and professionally specified interior projects.

Contract Projects

Project buyers requiring coordinated curtain specifications and documentation.

Planning a hospitality package? See our hotel curtains for hospitality projects.

Manufacturing & QC

A controlled path from specification to finished curtain

STEP 01

Requirement Review

Confirm market, application, selected material and required documentation.

STEP 02

Sample Approval

Review fabric, color, construction and workmanship before bulk production.

STEP 03

Cutting & Sewing

Produce to the approved finished dimensions and heading details.

STEP 04

QC & Document Check

Check finished curtains and align applicable documents with the approved specification.

View an existing selected product: faux linen flame retardant blackout curtains.

FAQ

Flame retardant curtain sourcing questions

Do all Dairui curtains pass NFPA 701?

No. Test evidence applies only to the specific material identified in the report. We confirm the selected fabric and project requirement before order approval.

Can you supply both FR-treated and inherently FR curtains?

Both routes can be discussed, subject to fabric availability, appearance requirements and the test documentation needed for the project.

What should I provide for an FR curtain quotation?

Share the project market, application, required test method, fabric or appearance direction, finished dimensions, heading style and documentation requirement.

Are flame retardant, fire retardant, fire resistant and fireproof curtains the same thing?

In curtain sourcing, flame retardant, fire retardant, flame resistant and fire resistant are generally used to describe the same requirement. Fireproof is not an accurate term for textiles: no curtain is proof against fire, and what is actually specified is flame-retardant performance measured against a named test standard such as NFPA 701 or CAN/ULC-S109. For project approval, confirm the applicable fabric and its test documentation rather than relying on the wording used in the enquiry.

Are these industrial fire or smoke barrier curtains?

No. This page covers interior textile curtains for hospitality, offices and commercial contract projects, not industrial fire curtains, welding curtains or fire/smoke barriers.

Can the report be used for a different fabric?

Not automatically. The tested sample and the proposed order fabric must be checked for an exact match, and project-specific testing may be required.

Discuss Your Flame Retardant Curtain Project

Tell us the project market, application, fabric direction and required test documentation. We will review the request against a suitable material route.

Ask for Samples Now!

We will arrange for a specialist to contact you immediately.

Ask for Quote Now

OEM & wholesale only. We do not sell single panels for personal or home use.

Email us